Source: Time:2022-08-10 22:40:36 views:

Simple Troubleshooting Methods for Metal Detectors

Simple Troubleshooting Methods for Metal Detectors


1. Conveyor belt deviation

    1) Determine whether the tension of the conveyor belt is appropriate. If the conveyor belt is too loose, it is easy to deviate.

    2) On the pallet bracket of the conveyor belt, there are two adjustment bolts near the outlet end of the conveyor belt, through which the tension of the conveyor belt can be adjusted.

    3) Observe whether the tension of the two sides is consistent. If the tension of both sides is inconsistent, it will also cause the conveyor belt to deviate.

    4) Adjust the tension of the two belts to the same level through these two adjusting bolts to solve the problem of conveyor belt deviation.


2. The instrument has no sensitivity


    1) Check whether there are large metal foreign objects in the probe hole, such as coins, keys, screws, etc., and remove metal impurities.

    2) Whether the product selection is correct.

    3) Whether it is selected to be in the NG prohibited state, in this state, the instrument will not perform alarm and elimination actions when it detects any metal, but the signal indicator will indicate.

    4) If the above conditions are ruled out and the instrument still has no detection sensitivity, please call our company.


3. The instrument periodically false alarm


    1) Whether the conveyor belt is contaminated by metal impurities, if the conveyor belt is contaminated by metal impurities, the detector will alarm whenever the contaminated part passes through the detection area. Clean the conveyor belt to remove metal impurities.

    2) Even if the conveyor belt does not rotate, the instrument still periodically falsely alarms. At this time, there may be a high-power interference source around the detector, such as a vibrating screen.


4. The instrument alarms irregularly


    1) The detector occasionally has irregular false alarms, which may be caused by unstable power supply. This can be solved by adding a regulated power supply.

    2) When the product is not detected, the instrument is normal. When the product to be detected passes through the detection area, it still alarms even if the product does not contain metal impurities, which indicates that the detection parameters are not properly adjusted. Please refer to Chapter 3.

    3) If there is still a false alarm after the conveyor belt stops, check whether there are high-power interference sources around the equipment, such as motors, engines, etc.

    4) Check for large pieces of moving metal around the device.

    5) Check whether the grounding wire of the power supply is in good condition. In order to ensure the stable operation of the instrument, a solid grounding wire is required.


5. The motor does not start


    1) On the control box panel, lightly press the "Start" and "Stop" buttons to observe whether the relays in the control module are active. If there is any action, the motor is damaged or the starting capacitor is damaged. You can buy the same type of motor and replace it. Or contact the company's after-sales service department. Non-professionals are not allowed to repair without authorization to prevent the danger of electric shock.

    2) If the relay does not act, the control module may be damaged, or the connecting wire may be loose. Eliminate the loose connection cable and observe whether the fault is eliminated. If the motor still does not start, please also contact the company's after-sales service department. Non-professionals are not allowed to repair without authorization, in order to prevent improper repair and damage to other parts.


6. The product passes through the detector head, and there is no metal impurities, and the alarm is also issued


    1). When the product passes through the detector head, and there is no metal impurities, it will also alarm, indicating that the detection parameters are not properly debugged.

    2). Check whether it is a product that has been debugged. If the detection product is not set, you need to re-debug the detection parameters


Links

久久婷婷国产|欧美成人精品二区三区99精品 |久久久久久久久久99精品|夫の137上司人妻中文字幕

欧洲无人区卡一卡二卡三| 少妇极品熟妇人妻丰满| 国产亚洲精品久久久久久久久久久动漫 | 国产亚洲精品久久久久久| 国产亚洲精品久久久久久久久动漫| 伊人精品一区二区三区| 国产人伦激情在线观看| 四川妇女搡bbbb搡bbbb搡′一| 精品人妻中文| 国产黄片在线视频| 成人午夜视频在线观看免费| 蜜桃色网| 久久老熟女| 中国熟妇厨房xxxxx乱| 婷婷色国产| av日韩中文字幕| 少妇一区二区三区在线观看免费视频 | 国产av一二区| 色一情一区二| 99热这里只有精品2| 啊灬啊灬啊灬快灬大水啊灬| 国产日韩欧美激情| 国产精品又长又粗又爽又黄的毛片 | 亚洲国产精品成人久久久麻豆| 爱爱网成人免费视频| 日韩精品人妻中文| 在线观看日本| 成人av免费网站| 美女丝袜一区二区三区| 天天干天天天干| 女人下边被添全过程视频| 精品无码人妻一区二区三区| 久久久久国产精| 国产熟妇高潮呻吟喷水| 婷婷久久精品| 人妻在线免费观看视频| xxx欧美一级内射直播| 国产V亚洲V天堂无码久久久| 欧美二区乱c黑人| 91人妻人人澡人人爽人人精品麻豆| 九色一区二区|